Message Error 075: Invalid Zone Set Size
Description The zone set entered exceeds switch NVRAM limitations.
Action Reduce the size of the zone set to meet specified requirements. This
can be a reduction in the number of zones in the zone set, a reduction
of members in a zone, or a reduction of zone name lengths.
Message Error 076: Invalid Number of Unique Zone Members
Description The zone entered contains more than the maximum number of zone
members allowed per zone set for this product.
Action Reduce the number of members in one or more zones and re-submit
the command.
Message Error 077: Not Allowed While Port Is Failed
Description The port selected is in a failed or inactive state, or is in need of
service.
Action Consult the installation/service manual for appropriate action.
Message Error 078: System Error Light On
Description This unit is not able to beacon because the system error light is on.
Action You must clear the system error light before unit beaconing may be
enabled. Consult the installation/service manual for appropriate
action.
Message Error 079: FRU Failed
Description The specified FRU has failed.
Action Consult the installation/service manual for appropriate action.